Skip to main content

Table 2 Values of KC200GT PV module noticed from CS algorithm (Al Hajri et al., 2012)

From: Effect of various parameters on the performance of solar PV power plant: a review and the experimental study

(a) SDM parameters (extracted by the CS algorithm)

\(I_{{{\text{PV}}}}\)

\(I_{{\text{O}}}\)

\(n\)

\(R_{{\text{S}}}\)

\(R_{{\text{P}}}\)

  

8.1715

4.24E−10

1.0089

0.2655

140.58

  

(b) Based on the CS code the obtained ISDM parameters

\(I_{{{\text{PVM}}}}\)

\(I_{{{\text{ON}}}}\)

\(n\)

\(R_{{{\text{SN}}}}\)

\(R_{{{\text{PM}}}}\)

\(K_{i}\)

\({\text{Egn}}\)

8.184

5.12E−10

1.010

0.257

117.92

0.002

1.247