Skip to main content

Table 5 Design specifications for preliminary scoping

From: Large-scale solar system design, optimal sizing and techno-economic-environmental assessment

Specifications of Kuala Langat, Selangor

Specifications of Kluang, Johor

System Components and Matrices

Data

System Components and Matrices

Data

Modules

Malaysian Solar, MYS-72P/B3/CF-300 (300W)

Modules

Malaysian Solar, MYS-72P/B3/CF-300 (300W)

Inverters

Solaron 250 kW

Inverters

Solaron 250 kW

String wiring

10 AWG (Copper)

String wiring

10 AWG (Copper)

Performance ratio

79%

Performance ratio

79.4%

Irradiance

kWh/m2

Irradiance

kWh/m2

Energy

kWh

Energy

kWh

Racking

Fixed Tilt

Racking

Fixed Tilt

Module azimuth

180°

Module azimuth

180°

Cells per string

19–21

Cells per string

19–21

Cells spacing

0.05 ft

Cells spacing

0.05 ft

Setback

8 ft

Setback

10 ft

DC/AC ratio

1.24

DC/AC ratio

1.24

Weather dataset

TMY, 10 km Grid, meteonorm

Weather dataset

TMY, 10 km Grid, meteonorm

Solar angle location

Meteo Lat/Lng

Solar angle location

Meteo Lat/Lng

Transposition model

Perez Model

Transposition model

Perez Model

Temperature model

Sandia Model

Temperature model

Sandia Model

Soiling

2%

Soiling

2%

Irradiance variance

5%

Irradiance variance

5%

Cell temperature spread

4 °C

Cell temperature spread

4 °C

Module binning range

−2.5 to 2.5%

Module binning range

−2.5 to 2.5%

AC system derate

0.50%

AC system derate

0.50%