Skip to main content

Table 7 Summary of Preliminary Scoping

From: Large-scale solar system design, optimal sizing and techno-economic-environmental assessment

Kuala Langat, Selangor

Kluang, Johor

System metrices

Results

System metrices

Results

Annual energy production

13,674,600 kWh

Annual energy production

15,842,300 kWh

Performance ratio

79.0%

Performance ratio

79.4%

kWh/kWp

1256.1

kWh/kWp

1265.6

Number of modules

36288

Number of modules

41724

Number of inverters

35

Number of inverters

41

Number of strings

1785

Number of strings

2050