Table 4 Rising and settling time pattern for optimal controller, suboptimal controller and optimal controller using pole placement technique for ω

From: Optimal and suboptimal controller design for wind power system

Point Rising time (s) Settling time (s)
Optimal controller using full-state feedback Suboptimal controller using output feedback Optimal controller using pole placement technique Optimal controller using full-state feedback Suboptimal controller using output feedback Optimal controller using pole placement technique
0.35 1.3e−018 1.3e−018 1.3e−018 3.49 3.29 2.48
0.65 0 1.3e−018 0 2.33 2.32 2.37
0.8 8.67e−019 8.67e−019 0 2.43 2.43 1.74
1.0 0 0 0 4.66 4.66 3.83