From: Optimal and suboptimal controller design for wind power system
Point | Rising time (s) | Settling time (s) | ||||
---|---|---|---|---|---|---|
Optimal controller using full-state feedback | Suboptimal controller using output feedback | Optimal controller using pole placement technique | Optimal controller using full-state feedback | Suboptimal controller using output feedback | Optimal controller using pole placement technique | |
0.35 | 1.3e−018 | 1.3e−018 | 1.3e−018 | 3.49 | 3.29 | 2.48 |
0.65 | 0 | 1.3e−018 | 0 | 2.33 | 2.32 | 2.37 |
0.8 | 8.67e−019 | 8.67e−019 | 0 | 2.43 | 2.43 | 1.74 |
1.0 | 0 | 0 | 0 | 4.66 | 4.66 | 3.83 |