Table 1 Amount of distilled water and hot brine water obtained from testing

From: Experimental study of an inclined flat plate-type solar water distillation system

Sl. no. Distilled water (l/h per m2) Hot brine water (l/h per m2) Global radiation (kWh/m2)
1. 0.67 1.53 6.2
2. 0.58 1.62 5.6
3. 0.49 1.71 5.01
4. 0.37 1.83 3.78
5. 0.42 1.78 4.37