From: Wind turbine performance analysis for energy cost minimization
Model | Location | Hub height (m) | Quantity | Cost/C.O.E. ($) | Cost/NPC (m$) | Unmet load |
---|---|---|---|---|---|---|
1.5 SLE | North | 85 | 7 | 0.171 | 30.7 | 73.5 |
1.5 SLE | South | 85 | 7 | 0.089 | 30.7 | 49.5 |
E44 | North | 55 | 11 | 0.303 | 32.2 | 84.3 |
E44 | South | 55 | 11 | 0.135 | 32.2 | 64.7 |
E53 | North | 85 | 13 | 0.163 | 30.5 | 72.5 |
E53 | South | 85 | 13 | 0.088 | 30.5 | 49 |
FD21-100 | North | 42 | 100 | 0.290 | 42.1 | 78.6 |
FD21-100 | South | 42 | 100 | 0.144 | 42.1 | 57 |
DW54 | North | 75 | 20 | 0.119 | 28.7 | 64.5 |
DW54 | South | 75 | 20 | 0.071 | 28.7 | 40 |
H25.0–200 kW | North | 40 | 50 | 0.132 | 20.4 | 77.3 |
H25.0–200 kW | South | 40 | 50 | 0.070 | 20.4 | 57.2 |