Skip to main content

Table 7 Confirmation of experiment results

From: Multi-thermal performance optimization of semi-circular heat pipes integrated with various solar collector profiles

Thermal performance Optimal Standard error fitness 95% confidence interval 95% PI
TE of V-trough 17.23 0.25 (16.45, 17.56) (16.25, 18.310)
TR of V-trough 0.05618 0.00416 (0.0435, 0.0565) (0.04211, 0.0614)
HO of V-Trough 89.43 2.92 (83.56, 94.24) (81.35, 95.56)
TE of V-groove 38.20 1.54 (34.99, 41.41) (32.46, 43.94)
TR of V-groove 0.097780 0.000235 (0.098270, 0.097290) (0.098657, 0.096903)
HO of V-groove 208.30 6.42 (194.90, 221.69) (184.31, 232.28)
TE of flat 20.167 0.274 (19.595, 20.738) (19.144, 21.190)
TR of flat 0.06957 0.00216 (0.06507, 0.07408) (0.06151, 0.07764)
HO of flat 110.43 1.92 (106.43, 114.44) (103.26, 117.61)