Skip to main content

Table 1 Summary of the calculated results

From: Modeling and experimental evaluation of a small-scale fresnel solar concentrator system

 

Initial

Preloaded

Final

Absolute pressure (×10−1MPa)

1.01

1.39

2.50

Temperature (°C)

100.00

109.01

126.86

Piston displacement (×10−2 m)

0

1.37

3.67

Spring force (N)

0

23.98

64.23

Total volume (×10−4m3)

5.30

5.39

5.54

Quality x (×10−6)

0

5

30

u f specific internal energy of liquid (kJ/kg)

418.75

456.97

532.89