Skip to main content

Advertisement

Table 2 Hourly variation of temperature of hot water, inside water temperature, outer cover sheet temperature, ambient temperature, and fresh water generation

From: Experimental study of an inclined flat plate-type solar water distillation system

Sl. no. Time Temperature of hot water (T 0, °C) Inside water temperature (T w, °C) Outer cover sheet temperature (°C) Ambient temperature (T i, °C) Wind speed (m/s) Fresh water (l/h/m2)
1. 9:00 38 50 41 2.8 2.8 0.234
2. 10:00 42 52 46 24.3 4.2 0.396
3. 11:00 50 59 53 24.7 4.6 0.528
4. 12:00 51 64 55 25.8 3.8 0.785
5. 13:00 52 65 56 28.7 3.1 0.799
6. 14:00 51 62 56 27.9 1.8 0.687
7. 15:00 49 60 55 25 1.6 0.623
8. 16:00 44 53 47 23.8 1.7 0.391
9. 17:00 46 51 48 23.5 1.72 0.294