Skip to main content

Table 12 Component sizing and quantities for LSSPV sites

From: Large-scale energy storage system: safety and risk assessment

Subsystem

Components

Unit

Site

   

A‐ Kuala Selangor

B‐ Batang Padang

   

A1

A2

B1

B2

B3

B4

B5

LSSPV + BESS

 

Size

Total capacity

MW

13.0

  

50.0

    
 

A–storage/LSSPV output

%

 

20–30

40–60

20

30

40

50

60

PV modules

PV module rating

W

550.0

       
 

No. PV modules

 

29,457

  

109096

    
 

No. strings

  

1091

1091

4196

4196

4196

4196

4196

Balance of system

 
 

String fuse

  

1091

1091

4196

4196

4196

4196

4196

 

DC switch

  

8

8

11

11

11

11

11

 

AC circuit breaker

  

8

8

11

11

11

11

11

 

Central inverter

MVA

2.0

  

4.2

    
 

No of inverters

  

8

8

11

11

11

11

11

Battery energy

 

Storage

Li‐NMC BESS unit size

kWh

2510

  

4184

    
 

Total BESS capacity

MWh

 

5.02

10.04

16.74

25.10

33.47

41.84

46.02

 

No. of BESS units

  

2

4

4

6

8

10

11

 

No. battery racks/unit

  

12

12

20

20

20

20

20

 

Total battery racks

  

24

48

80

120

160

200

220